Test Setup
Ch 0 to Ch 7 of QT150 card 0 is connected from the tuner, to the 8 test points. In order to accomplish this, we can't with just one mux card ( i.e. with only 64 channels). More advanced method of interfacing can be accomodated with the Bed of Nails and the solenoids to actuate the UUT (Unit Under Test) test fixture
Learning
The test software provides features to learn all the 8 test points with different voltage and different frequency settings with the QSM through the fixture setup
Report
The user can choose to print out the results at the end of the test. This feature enable even the lowest-level operator to use the QT150
A typical error log looks like this:
Tested Board ID : B0
Master Board : THOMAS
Test began at 13:30:13 - 10/01/96
and ends at 13:31:59 - 10/01/96
Board B0 Fails
Device TEST1 Fails
ADDITIONAL LINKS FOUND :-
Pin 1 shorted to : 7, 8
Pin 7 shorted to : 8
Pin 8 shorted to : 9
-----------------------------------------
Pin No Failure % Failure % HiZ Pins
Missing Links Additional Links
Occurance Deviation with Pins with Pins
-----------------------------------------
7 87.5% 96% - (8) ---- ---- Yes
1 25.0% 94% - (7) ---- ---- Yes
4 25.0% 48% - (7)
2 25.0% 35% - (7)
3 25.0% 39% - (7)
6 25.0% 26% - (7)
9 25.0% 94% - (7)
-----------------------------------------
LIST OF DEVIATIONS THAT OCCURED >= 0.0%
TEST1-1 - TEST1-7 short fails!
94 %
TEST1-1 - TEST1-8 short fails! 61 %
TEST1-2 - TEST1-7 Trace fails! 35 %
TEST1-2 - TEST1-8 Trace fails! 27 %
TEST1-3 - TEST1-7 Trace fails! 39 %
TEST1-3 - TEST1-8 Trace fails! 31 %
TEST1-4 - TEST1-7 Trace fails! 48 %
TEST1-4 - TEST1-8 Trace fails! 33 %
TEST1-6 - TEST1-7 Trace fails! 26 %
TEST1-6 - TEST1-8 Trace fails! 13 %
TEST1-7 - TEST1-8 short fails! 96 %
TEST1-7 - TEST1-9 Trace fails! 94 %
TEST1-8 - TEST1-9 short fails! 61 %
-------- End Of Board Result --------
Error Log/Report Contents
Contents copyright © 1998-2005 Qualectron Systems Corporation. For comments,
inquiries or suggestions about this Web site, send e-mail to info@qualectron.com